Serial Dilution Calculator: Step-by-Step Dilution Series
Small steps to a very low concentration.
A serial dilution reduces a concentration by the same factor in each step, which reaches very low levels with manageable volumes. Enter the starting concentration, the dilution factor, the number of steps and the volume per tube, and the calculator gives the final concentration and how much to transfer and add each time. The table compares five common dilution series.
Your details
Try an example
Result
Final concentration
1e-6
After 6 × 10-fold dilutions · total dilution 1 : 1,000,000
- Transfer each step
- 0.1 mL
- Diluent each tube
- 0.9 mL
- Total dilution
- 1 : 1,000,000
Good to know: concentration after n steps = start ÷ factor^n
How it was worked out · notes
- Transfer volume = final volume ÷ dilution factor = 1 ÷ 10 = 0.1 mL
- Diluent = 1 − 0.1 = 0.9 mL
- Concentration after n steps = 1 ÷ 10ⁿ
- Mix each tube thoroughly before transferring, and use a fresh pipette tip each time. Real serial dilutions carry small pipetting errors that add up along the series.
Tube by tube
Move 0.1 mL from each tube into 0.9 mL of diluent in the next.
| Tube | Concentration | Total dilution | Transfer in | Diluent |
|---|---|---|---|---|
| Stock | 1 | 1 : 1 | – | – |
| 1 | 0.1 | 1 : 10 | 0.1 mL | 0.9 mL |
| 2 | 0.01 | 1 : 100 | 0.1 mL | 0.9 mL |
| 3 | 0.001 | 1 : 1,000 | 0.1 mL | 0.9 mL |
| 4 | 0.0001 | 1 : 10,000 | 0.1 mL | 0.9 mL |
| 5 | 1e-5 | 1 : 100,000 | 0.1 mL | 0.9 mL |
| 6 | 1e-6 | 1 : 1,000,000 | 0.1 mL | 0.9 mL |
Please note: For study and planning. Check calculations independently before using results with chemicals, electricity, pressure or machinery, and follow safety data sheets, manufacturer instructions and local regulations.
The idea behind it
What is going on inside the serial dilution calculator
01Method
Each tube comes from the one before
Moving a fixed volume into fresh diluent at every step cuts the concentration by the same factor each time.
02Notation
1:10 means a factor of ten
One part sample in ten parts total is a ten-fold dilution. The total after several steps is the product of the factors.
03Accuracy
Errors compound
Each pipetting error carries into the next tube, so mix well, change tips and keep volumes large enough to measure accurately.
Five dilution series from the same stock
Small dilution factors give many gentle steps, while large ones plunge quickly. Each series starts at a concentration of 1 and uses 1 mL tubes.
| Series | Final concentration | Total dilution | Transfer each step |
|---|---|---|---|
| Two-fold, 8 steps | 0.0039063 | 1 : 256 | 0.5 mL |
| Three-fold, 7 steps | 0.00045725 | 1 : 2,187 | 0.3333 mL |
| Five-fold, 5 steps | 0.00032 | 1 : 3,125 | 0.2 mL |
| Ten-fold, 6 steps | 1e-6 | 1 : 1,000,000 | 0.1 mL |
| Hundred-fold, 4 steps | 1e-8 | 1 : 100,000,000 | 0.01 mL |
Concentrations are relative to the starting stock of 1. The transfer volume is the tube volume divided by the dilution factor.
Starting concentration, factor and number of steps
- Enter the starting concentration and the dilution factor per step.
- Enter the number of dilutions and the final volume in each tube.
- Read the transfer and diluent volumes.
- Follow the table tube by tube.
Six ten-fold steps from 1 unit
A 1:10 series of 6 tubes starting at 1 with 1 mL in each tube transfers 0.1 mL and adds 0.9 mL of diluent each time. The last tube is 1 × 10⁻⁶ of the stock.
Method and reference points
Formula
concentration after n steps = start ÷ factor^n
Not mixing each tube before the next transfer
- Adding the transfer volume to the diluent instead of making up to the final volume.
- Forgetting to mix between steps.
- Reusing the same pipette tip.
- Confusing the dilution factor with the ratio, such as 1:10 against 1:9.
Dilution series questions
How do I do a 1:10 serial dilution?
Mix 1 part of the previous tube with 9 parts of diluent in the next tube, mix well, and repeat. Each tube is a tenth of the concentration of the one before.
What is a serial dilution?
A series of dilutions in which each tube is made from the one before, so the concentration falls by the same factor every step. Common in microbiology and assays.
What does a 1:10 dilution mean?
One part sample plus nine parts diluent, a ten-fold dilution in total. The dilution factor is 10.
How do I get the total dilution?
Multiply the factors of all the steps. Six ten-fold steps give 10⁶, or 1 : 1,000,000.
Related tools
- Concentration ConverterConvert between g/L, molarity, percent w/v, percent w/w, ppm and molality for a solution.
- Molality and Mole Fraction CalculatorFind molality, mole fraction and mass percent from the masses of solute and solvent.
- Molarity CalculatorCalculate molarity, moles of solute or solution volume.
- Dilution Calculator (C1V1 = C2V2)Work out how much stock solution and solvent you need to reach a target concentration.
How we calculate this
We use the standard published formula or definition for this calculation, and we show the working so you can check it.
Spotted a mistake? Tell us and we'll check it. How we check our calculators