Skip to content
Convert. Calculate.

Hydroelectric Power Calculator: What Can a Stream Generate?

Fall and flow decide the watts.

Small hydropower depends on two things: how far the water falls and how much of it flows.

Your details

Try an example

Result

Currency

Power output

6.86 kW

About 54,121 kWh a year · worth $8,659

Power
6.86 kW
Energy per year
54,121 kWh
Worth per year
$8,659
Power rises in step with flow (twice the flow, twice the power)
-5.4914.935.355.776.10125250375500YouFlow, litres per secondPower, kW
Image

Good to know: P = ρ × g × H × Q × η

The numbers behind this · totals, working, notes
Power before losses
9.81 kW
Flow
793 US gpm · 0.050 m³/s
Head
66 ft

How it was worked out

P = ρ × g × H × Q × η

  1. ρ = 1,000 kg/m³ (water), g = 9.80665 m/s²
  2. Power = 1000 × 9.80665 × 20 m × 0.050 m³/s × 0.7 = 6,865 W
  3. Energy per year = 6.86 kW × 8,760 hours × 0.9 = 54,121 kWh
  • Head is the vertical drop from intake to turbine. Flow varies with the seasons, so use the flow you can rely on for most of the year. Permits and water rights often apply to taking water from a stream.

Power for other flows

Same head and efficiency. Your flow is highlighted.

FlowPowerEnergy per year
10 L/s1.37 kW10,824 kWh
25 L/s3.43 kW27,060 kWh
50 L/s6.86 kW54,121 kWh
100 L/s13.73 kW108,242 kWh
200 L/s27.46 kW216,484 kWh
500 L/s68.65 kW541,209 kWh

Power for other heads

Same flow and efficiency. Your head is highlighted.

HeadPower
5 m1.72 kW
10 m3.43 kW
20 m6.86 kW
50 m17.16 kW
100 m34.32 kW

The idea behind it

Three ideas that explain the hydroelectric power calculator

  • 01Head

    Vertical drop matters most

    Head is the vertical distance the water falls. A small stream with high head can give more power than a big, flat river.

  • 02Flow

    Use a dependable flow

    Flow changes with the seasons, so base the design on the flow available for most of the year, not the wettest day.

  • 03Efficiency

    Losses in the pipe and turbine

    Friction in the pipe, the turbine and the generator reduce the output. Small schemes often reach 50 to 70 percent overall.

Five water sources, five power outputs

A high drop with a modest flow can beat a big, lazy river: power is proportional to head times flow. These five illustrative sites use the same 70% efficiency.

Five water sources, five power outputs
SiteHead (m)Flow (L/s)Power outputEnergy per year
Garden stream35103 W812 kWh
Mill leat22002.75 kW21,648 kWh
Farm creek15303.09 kW24,354 kWh
Mountain stream804021.97 kW173,187 kWh
Small river scheme10100068.65 kW541,209 kWh

Illustrative sites. Real schemes need permission, a survey of seasonal flow and turbine choice matched to head and flow.

Head, flow and efficiency

  1. Enter the head, the vertical drop in metres.
  2. Enter the flow in litres per second.
  3. Enter the overall efficiency and the share of the year the system runs.
  4. Read the power, yearly energy and the tables for other flows and heads.

A 20 m drop at 50 L/s

A 20 m head with 50 L/s and 70% efficiency gives 1,000 × 9.80665 × 20 × 0.05 × 0.7 ≈ 6.86 kW. Running 90% of the year it makes about 54,000 kWh.

The formula and reference values

Formula

P = ρ × g × H × Q × η

Measuring the length of the pipe instead of the vertical drop

  • Using the length of the pipe instead of the vertical drop.
  • Entering flow in litres per minute instead of per second.
  • Using the flood flow instead of a dependable one.
  • Forgetting permits and water rights.

Micro-hydro questions

What do head and flow mean in hydropower?

Head is the vertical drop of the water, and flow is the volume passing each second. Power is proportional to both, so either a high drop or a large flow can give a useful output.

What is head in hydropower?

The vertical distance the water falls between the intake and the turbine. Power is proportional to head, so a higher drop gives more power for the same flow.

What efficiency should I use?

Small systems commonly reach 50% to 70% overall once pipe friction, the turbine and the generator are counted. Large plants are higher.

How much water do I need?

Enough flow through the head for the power you want. At a 20 m head, roughly 5 L/s gives about 0.7 kW after losses.

Related tools

How we calculate this

We use the standard published formula or definition for this calculation, and we show the working so you can check it.

Spotted a mistake? Tell us and we'll check it. How we check our calculators